Resource Type

Journal Article 1612

Conference Videos 116

Conference Information 3

Conference Topics 1

Year

2024 3

2023 143

2022 214

2021 169

2020 122

2019 103

2018 111

2017 90

2016 74

2015 115

2014 70

2013 79

2012 45

2011 69

2010 62

2009 46

2008 33

2007 32

2006 20

2005 14

open ︾

Keywords

energy 28

renewable energy 25

energy consumption 24

solar energy 21

China 18

energy efficiency 18

sustainable development 18

energy security 17

high-quality development 16

energy saving 15

energy revolution 14

development strategy 13

optimization 11

energy transition 10

water quality 10

quality 9

carbon neutrality 8

wind power 8

climate change 7

open ︾

Search scope:

排序: Display mode:

Decoupling optimization of integrated energy system based on energy quality character

Shixi MA, Shengnan SUN, Hang WU, Dengji ZHOU, Huisheng ZHANG, Shilie WENG

Frontiers in Energy 2018, Volume 12, Issue 4,   Pages 540-549 doi: 10.1007/s11708-018-0597-4

Abstract: various energy equipment such as gas-fired power plants and electricity-driven gas compressor.Therefore, the integrated energy system has attracted much attention.quality character after considering the grade difference of the energy loss of the subsystem, and findsan optimal scheduling method for integrated energy systems.system composed of an IEEE 39 nodes power system and a 10 nodes natural gas system.

Keywords: integrated energy system     energy quality character     optimization     electric power system     natural gas system    

Unified power quality conditioner based on a three-level NPC inverter using fuzzy control techniques

Salim CHENNAI,M-T BENCHOUIA

Frontiers in Energy 2014, Volume 8, Issue 2,   Pages 221-239 doi: 10.1007/s11708-014-0317-7

Abstract: This paper presents a novel and efficient control scheme for unified power quality conditioner (UPQC)The synchronous reference frame (SRF) theory is used to get the reference signals for shunt active powerfilters (APFs) and the power reactive theory (p-q theory) for series APFs.The performances of the proposed UPQC system are evaluated in terms of power factor correction, mitigationenergy quality.

Keywords: three-level neutral point clamped (NPC) inverter     unified power quality conditioner (UPQC)     current harmonicsmitigation     fuzzy logic controller     voltage disturbance compensation     shunt active filter     series active filter     powerquality energy improvement    

Strategy of Manufacturing Quality Power

The Research Group for Manufacturing Quality Power Strategy

Strategic Study of CAE 2015, Volume 17, Issue 7,   Pages 24-28

Abstract:

The meaning to implement the Manufacturing Quality Power Strategy was systematically discussed inthis research, and the present situation of manufacturing quality development in our country was analyzed

Keywords: manufacturing power     quality     strategy    

Effect of harmonic distortion on electric energy meters of different metrological principles

Illia DIAHOVCHENKO, Vitalii VOLOKHIN, Victoria KUROCHKINA, Michal ŠPES, Michal KOSTEREC

Frontiers in Energy 2019, Volume 13, Issue 2,   Pages 377-385 doi: 10.1007/s11708-018-0571-1

Abstract: This paper deals with the errors of electric energy metering devices as a result of distortions in theIt is shown and proved that the errors in energy measurements depend on the design and the algorithmsharmonic distortions and the constant component which occur in the network while others measure the powerand energy values of the fundamental harmonic only.Such traits lead to the discrepancies in the readings of commercial electric energy meters of different

Keywords: current     distortion     electric energy meter     harmonics     power quality    

Impact of energy structure adjustment on air quality: a case study in Beijing, China

Bin ZHAO, Jiayu XU, Jiming HAO

Frontiers of Environmental Science & Engineering 2011, Volume 5, Issue 3,   Pages 378-390 doi: 10.1007/s11783-011-0357-8

Abstract: Energy consumption is a major cause of air pollution in Beijing, and the adjustment of the energy structurefive energy scenarios focusing on the fuel substitution in power plants and heating sectors, establishedBy fuel substitution for power plants and heating boilers, PM , PM , SO , NO , and NMVOCs will be reducedof air quality improvement due to structure adjustment in power plants and heating sectors is limitedof air quality standards.

Keywords: Beijing     energy structure adjustment     air quality     Community Multiscale Air Quality Model (CMAQ)     scenario    

Novel quantum-inspired firefly algorithm for optimal power quality monitor placement

Ling Ai WONG,Hussain SHAREEF,Azah MOHAMED,Ahmad Asrul IBRAHIM

Frontiers in Energy 2014, Volume 8, Issue 2,   Pages 254-260 doi: 10.1007/s11708-014-0302-1

Abstract: The application of a quantum-inspired firefly algorithm was introduced to obtain optimal power qualitymonitor placement in a power system.

Keywords: quantum-inspired binary firefly algorithm     topological monitor reach area     power quality    

Rapid transaction to load variations of active filter supplied by PV system

M. BENADJA,S. SAAD,A. BELHAMRA

Frontiers in Energy 2014, Volume 8, Issue 3,   Pages 335-344 doi: 10.1007/s11708-014-0325-7

Abstract: This development is based on the control of the Boost converter to extract the maximum power from theThe proposed modeling and control strategy provide power to the variable nonlinear load and facilitatesthe transfer of power from solar panel to the grid while improving the quality of energy (harmonic currentscompensation, power factor compensation and dc bus voltage regulation).Validation of the developed model and control strategy is conducted using power system simulator Sim-Power

Keywords: solar panels     maximum power point tracking (MPPT)     DC/DC converter (Boost)     shunt active filter     instantaneouspower control     power quality     harmonics     imbalances     reactive energy    

Influence of increasing numbers of RE-inverters on the power quality in the distribution grids: A PQ

Przemyslaw JANIK, Grzegorz KOSOBUDZKI, Harald SCHWARZ

Frontiers in Energy 2017, Volume 11, Issue 2,   Pages 155-167 doi: 10.1007/s11708-017-0469-3

Abstract: This paper presents the selected power quality (PQ) indicia of a wind generator and a photovoltaic installationOn the other hand, fluctuations in power generation are regarded as an emerging PQ indicator.growing number of distributed renewable installations causes stochastic, variable, and hardly predictable power

Keywords: power quality     harmonics     sags     photovoltaic(PV) system     doubly feed induction generator (DFIG)     inverters    

Optimal operation of integrated energy system including power thermal and gas subsystems

Frontiers in Energy 2022, Volume 16, Issue 1,   Pages 105-120 doi: 10.1007/s11708-022-0814-z

Abstract: As a form of hybrid multi-energy systems, the integrated energy system contains different forms of energysuch as power, thermal, and gas which meet the load of various energy forms., the dist-flow method is applied to quickly calculate the power flow and the gas system model is builtby the analogy of the power system model.The power-thermal-gas integrated energy system used in the case study includes an IEEE-33 bus power system

Keywords: integrated energy system     power-to-gas     dist-flow     piecewise linearization     alternating direction method    

Analysis and prediction of the influence of energy utilization on air quality in Beijing

LI Lin, HAO Jiming, HU Jingnan

Frontiers of Environmental Science & Engineering 2007, Volume 1, Issue 3,   Pages 339-344 doi: 10.1007/s11783-007-0058-5

Abstract: This work evaluates the influence of energy consumption on the future air quality in Beijing, using 2000It establishes the emission inventory of primary PM, SO and NO related to energy utilization in eightThe air quality model was adopted to simulate the temporal and spatial distribution of each pollutantAccording to the current policy and development trend, air quality in the eight urban areas could becomebetter in 2008 when the average concentrations of primary PM, SO and NO related to energy utilization

Renewable power for China: Past, present, and future

Eric MARTINOT

Frontiers in Energy 2010, Volume 4, Issue 3,   Pages 287-294 doi: 10.1007/s11708-010-0120-z

Abstract: capacity from renewable energy.Policy frameworks have matured and evolved since the landmark 2005 Renewable Energy Law, updated in 2009China’s 2020 renewable energy target is similar to that of the EU.Prospects for biomass power are limited by resource constraints.Other technologies such as concentrating solar thermal power, ocean energy, and electricity storage require

Keywords: renewable energy     wind power     solar power     sustainable energy policy     green industry    

Power quality improvement using fuzzy logic controller for five-level shunt active power filter under

Amar BENAISSA,Boualaga RABHI,Ammar MOUSSI

Frontiers in Energy 2014, Volume 8, Issue 2,   Pages 212-220 doi: 10.1007/s11708-013-0284-4

Abstract: In this paper, a five-level inverter is used as a shunt active power filter (APF), taking advantagesIt is used to compensate reactive power and eliminate harmonics drawn from a thyristor rectifier feeding

Keywords: active power filter (APF)     harmonics isolator     distorted voltage conditions     self-tuning filters (STF)     fuzzy    

Human power-based energy harvesting strategies for mobile electronic devices

Dewei JIA, Jing LIU

Frontiers in Energy 2009, Volume 3, Issue 1,   Pages 27-46 doi: 10.1007/s11708-009-0002-4

Abstract: new power sources should be developed.It has been gradually recognized that the human body is highly flexible in generating applicable powerwhich is strong enough to power mobile or even implantable medical devices which could be used for awhich would serve as promising candidates for future mobile power.Finally, future prospects in harvesting energy from human power are made in conclusion.

Keywords: mobile electronic device     human power     energy harvesting     micro/miniaturized generator     battery     green energy    

Combined heat and power plant integrated with mobilized thermal energy storage (M-TES) system

Weilong WANG, Yukun HU, Jinyue YAN, Jenny NYSTR?M, Erik DAHLQUIST

Frontiers in Energy 2010, Volume 4, Issue 4,   Pages 469-474 doi: 10.1007/s11708-010-0123-9

Abstract: Energy consumption for space and tap water heating in residential and service sectors accounts for onethird of the total energy utilization in Sweden.District heating (DH) is used to supply heat to areas with high energy demand.In this paper, the integration of a combined heat and power (CHP) plant and an M-TES system is analyzedFurthermore, the impacts of four options of the integrated system are discussed, including the power

Keywords: Mobilized thermal energy system     district heating     thermal energy storage     combined heat and power     detached    

Integrated energy in Germany–A critical look at the development and state of integrated energies in Germany

Saman AMANPOUR, Daniel HUCK, Mark KUPRAT, Harald SCHWARZ

Frontiers in Energy 2018, Volume 12, Issue 4,   Pages 493-500 doi: 10.1007/s11708-018-0570-2

Abstract: In the face of global warming and a scarcity of resources, future energy systems are urged to undergoThe recognition of the need to embrace renewable energy technologies and to move toward decarbonizationhas led to significant changes in the German energy generation, consumption and infrastructure.This paper discusses the role of integrated energy systems in supporting of sustainable solutions forfuture energy transitions.

Keywords: integrated energy     renewable energies     energy transition     power-to-gas     power-to-heat     power-to-mobility     energy    

Title Author Date Type Operation

Decoupling optimization of integrated energy system based on energy quality character

Shixi MA, Shengnan SUN, Hang WU, Dengji ZHOU, Huisheng ZHANG, Shilie WENG

Journal Article

Unified power quality conditioner based on a three-level NPC inverter using fuzzy control techniques

Salim CHENNAI,M-T BENCHOUIA

Journal Article

Strategy of Manufacturing Quality Power

The Research Group for Manufacturing Quality Power Strategy

Journal Article

Effect of harmonic distortion on electric energy meters of different metrological principles

Illia DIAHOVCHENKO, Vitalii VOLOKHIN, Victoria KUROCHKINA, Michal ŠPES, Michal KOSTEREC

Journal Article

Impact of energy structure adjustment on air quality: a case study in Beijing, China

Bin ZHAO, Jiayu XU, Jiming HAO

Journal Article

Novel quantum-inspired firefly algorithm for optimal power quality monitor placement

Ling Ai WONG,Hussain SHAREEF,Azah MOHAMED,Ahmad Asrul IBRAHIM

Journal Article

Rapid transaction to load variations of active filter supplied by PV system

M. BENADJA,S. SAAD,A. BELHAMRA

Journal Article

Influence of increasing numbers of RE-inverters on the power quality in the distribution grids: A PQ

Przemyslaw JANIK, Grzegorz KOSOBUDZKI, Harald SCHWARZ

Journal Article

Optimal operation of integrated energy system including power thermal and gas subsystems

Journal Article

Analysis and prediction of the influence of energy utilization on air quality in Beijing

LI Lin, HAO Jiming, HU Jingnan

Journal Article

Renewable power for China: Past, present, and future

Eric MARTINOT

Journal Article

Power quality improvement using fuzzy logic controller for five-level shunt active power filter under

Amar BENAISSA,Boualaga RABHI,Ammar MOUSSI

Journal Article

Human power-based energy harvesting strategies for mobile electronic devices

Dewei JIA, Jing LIU

Journal Article

Combined heat and power plant integrated with mobilized thermal energy storage (M-TES) system

Weilong WANG, Yukun HU, Jinyue YAN, Jenny NYSTR?M, Erik DAHLQUIST

Journal Article

Integrated energy in Germany–A critical look at the development and state of integrated energies in Germany

Saman AMANPOUR, Daniel HUCK, Mark KUPRAT, Harald SCHWARZ

Journal Article